The Pramac P7500i is a larger portable petrol inverter generator with clean output and 2-wire auto start capability.
It is suited to sensitive electronics, mobile work, leisure power and selected backup applications.
Supported locally Installation available Technical advice, Australian Support
Product overview
The P7500i provides 230 V single-phase inverter output with higher output capacity than the smaller P inverter models.
It includes electric/recoil starting, economy mode, wheel/handle portability and 2-wire auto start support in the Australian configuration.
CPS can assist with confirming load suitability and matching the generator to transfer or remote start requirements.
7.0 kVA maximum / 6.5 kW rated inverter output
230 V, 50 Hz single-phase output
Pramac 192F petrol engine with electric/recoil starting
25 L tank with approximately 11 h run time
64 dB(A) noise pressure at 7 m
2-wire auto start capable Australian configuration
Behind the Brand
Meet the supported manufacturers whose components are specified in this product.
Equipment manufacturer
Pramac
Pramac is a leading global manufacturer of stationary and mobile power generation equipment, founded in Tuscany, Italy in 1966. Now part of the Generac group, Pramac engineers diesel, petrol and battery energy storage solutions trusted by rental houses, mining sites and emergency services in over 150 countries.
Ratings definitions (ISO 8528)
These definitions explain ISO 8528 rating terms where they are listed. Use the ratings specified for this model; maximum, continuous and other rating types are not interchangeable.
ESPEmergency Standby Power
Maximum available power for a variable electrical load during a utility outage or testing, under the stated operating conditions.
Up to 200 operating hours per year.
Average output over 24 hours must not exceed 70% of the ESP rating.
PRPPrime Power
Maximum available power for a variable electrical load over an unlimited number of operating hours per year, under the agreed operating conditions.
Average output over 24 hours must not exceed 70% of the prime-power rating.
Unlimited annual operating hours do not mean continuous operation at full rated output.
The manufacturer’s prescribed operating conditions, maintenance intervals and procedures apply to both ratings.
Product descriptions, specifications and photos are indicative only and may vary by model or configuration. Photos may show optional equipment. Please confirm the exact model, configuration, specifications, inclusions and availability with Gold Coast Generators before ordering.