Pramac PX8000
The PX8000 uses a roll-cage frame, integrated wheel kit, steel tank and digital display for practical site operation.
Automatic Voltage Regulation stabilises output voltage, while oil guard and thermal protection support reliable operation under portable load conditions.
CPS can assist with site distribution, safe connection and generator sizing.
- 6.0 kVA / 5.4 kW standby output
- 5.0 kVA / 4.5 kW continuous output
- 230 V, 50 Hz single-phase output at 0.9 power factor
- Pramac OHV SR190F petrol engine
- 27 L steel tank with approximately 13.5 h run time at 75% load
- 69 dB(A) noise pressure at 7 m
Industry-leading components, fully supported in Australia

Pramac
Pramac is a leading global manufacturer of stationary and mobile power generation equipment, founded in Tuscany, Italy in 1966. Now part of the Generac group, Pramac engineers diesel, petrol and battery energy storage solutions trusted by rental houses, mining sites and emergency services in over 150 countries.
- Model
- PX8000
- Prime / PRP output
- 5.4 kW
- Phase
- Single-phase
- Voltage
- 230 V
- Frequency
- 50 Hz
- Power factor
- 0.9
- Fuel
- Petrol
- Fuel Tank Size
- 27 L
- Fuel Consumption @ 75% Load
- 2.0 L/hr
- Dimensions (L × W × H)
- 727 × 515 × 670 mm
- Noise @ 7m
- 69 dB(A)
- Engine
- Pramac OHV SR190F
- Engine speed
- 3000 rpm
- Engine cooling
- Air
- Configuration
- Open frame on wheel kit
- Model code
- PK452SX2002
- Standby / LTP output
- 6.0 kVA / 5.4 kW
- Starting system
- Electric + Recoil
- Sockets
- 1 × 230 V Schuko 16 A IP54; 1 × 230 V CEE 16 A IP44; 1 × 230 V CEE 32 A IP44
- Displacement
- 420 cc
- Runtime @75% load
- 13.50 h
- Dry weight
- 94 kg
- Guaranteed sound power
- 97 LWA
- Voltage regulation
- AVR
- Voltage control
- AVR
- Alternator protection
- IP23
Learn more — Generator School
All guides →
Almost every conversation about generator sizing starts with two numbers: kVA and kW. They sound similar, they're closely related, and they're almost always mis-used. The beer-glass analogy below is the fastest way to get them straight in your head — and once you do, every spec sheet in the catalogue suddenly makes sense.

A generator is really three machines bolted together: an engine, an alternator, and a controller. They each do one job, and they all have to talk to each other for the unit to behave properly.

Almost every customer who asks us 'should I get diesel or petrol?' gets the same answer: it depends on the duty. For occasional camp / weekend use under 8 kVA, petrol is cheaper to buy and lighter to move. For anything that has to start reliably after sitting unused — backup, standby, prime-power — diesel wins, almost always.