Pramac P3500i
The P3500i combines inverter output with a larger 10 L tank and electric/recoil starting, giving a practical balance between clean power and portability.
It is designed for applications where low noise, economy mode and stable voltage are important.
CPS can assist with generator selection, connection accessories and backup application advice.
- 3.3 kVA maximum / 3.0 kW rated inverter output
- 230 V, 50 Hz single-phase output
- Pramac 170F petrol engine with electric/recoil starting
- 10 L tank with approximately 6.0 h run time
- 61 dB(A) noise pressure at 7 m
- Inverter output with economy mode and overload protection
Industry-leading components, fully supported in Australia

Pramac
Pramac is a leading global manufacturer of stationary and mobile power generation equipment, founded in Tuscany, Italy in 1966. Now part of the Generac group, Pramac engineers diesel, petrol and battery energy storage solutions trusted by rental houses, mining sites and emergency services in over 150 countries.
- Model
- P3500i
- Prime / PRP output
- 3.0 kW (real)
- Phase
- Single-phase
- Voltage
- 230 V
- Frequency
- 50 Hz
- Power factor
- 1.0
- Fuel
- Petrol
- Fuel Tank Size
- 10 L
- Fuel Consumption @ 75% Load
- 1.6 L/hr
- Fuel consumption
- 1.6 L/hr
- Dimensions (L × W × H)
- 601 × 458 × 552 mm
- Noise @ 7m
- 61 dB(A)
- Engine
- Pramac 170F
- Engine speed
- 3000 rpm
- Engine cooling
- Air
- Emissions level
- Stage V
- Configuration
- Compact inverter chassis
- Model code
- PF302SXB003
- Standby / LTP output
- 3.3 kVA
- Starting system
- Electric + Recoil
- Displacement
- 212 cc
- Runtime @75% load
- 6 h
- Dry weight
- 49.5 kg
- Guaranteed sound power
- 88 LWA
- Power
- 3.0 kW rated / 3.3 kW max
- Output power (rated)
- 3000 W
- Output power (max)
- 3300 W
- Voltage regulation
- Inverter
- Maximum output
- 3.3 kVA
- Rated output
- 3.0 kW
- Run time
- 6.0 h
- Voltage control
- Inverter
- Protection
- Overload; Oil Guard; short circuit; overvoltage; overtemperature
Learn more — Generator School
All guides →
Almost every conversation about generator sizing starts with two numbers: kVA and kW. They sound similar, they're closely related, and they're almost always mis-used. The beer-glass analogy below is the fastest way to get them straight in your head — and once you do, every spec sheet in the catalogue suddenly makes sense.

A generator is really three machines bolted together: an engine, an alternator, and a controller. They each do one job, and they all have to talk to each other for the unit to behave properly.

Almost every customer who asks us 'should I get diesel or petrol?' gets the same answer: it depends on the duty. For occasional camp / weekend use under 8 kVA, petrol is cheaper to buy and lighter to move. For anything that has to start reliably after sitting unused — backup, standby, prime-power — diesel wins, almost always.