LTS >1000-2500A
The NHP/Socomec LTS >1000-2500A is rated at 2500A. It suits applications where essential loads need to change between mains and generator supply automatically. Pair it with a compatible controller such as our DSE327, DSE331, DSE334, DSE335 or any of the generators we sell in the GSW, GDW, GPW and GRW range as these come standard with a mains failure controller. Do you already have a generator? Get in touch - we will see if your generator control system is compatible, or if you need one of the DSE controllers. CPS can assist with controller selection, configuration, switchboard design, generator integration, building load integration / compatibility, testing and commissioning with on-going support. Not just "ship it and forget about it".
- NHP/Socomec load transfer switch for mains-to-generator changeover applications
- 2500A transfer rating
- Compatible with DSE327, DSE331, DSE334, DSE335 and compatible mains-failure generator controllers
- CPS can assist with switchboard design, generator integration, testing and commissioning
Industry-leading components, fully supported in Australia

Pramac
Pramac is a leading global manufacturer of stationary and mobile power generation equipment, founded in Casole d'Elsa, Tuscany in 1966. Now part of the Generac group, Pramac engineers diesel, petrol and battery energy storage solutions trusted by rental houses, mining sites and emergency services in over 150 countries.
SOCOMEC
SOCOMEC has specialised in the availability, control and safety of low-voltage electrical networks since 1922. Its ATyS automatic transfer switching equipment is designed for controlled changeover between power sources, including mains-to-generator applications. Capital Power Systems can help select the correct SOCOMEC transfer switch, control arrangement and integration package for the generator, switchboard and site operating requirements.
- Model
- LTS >1000-2500A
- Phase
- Single- or three-phase depending switchgear configuration
- Compatible controllers
- DSE331, DSE334, DSE335 + Generator controllers with Mains Failure Detection & ATS Control. Contact us for assistance.
- Product type
- load transfer switch / automatic transfer switch
- Rated current
- 2500A
- Application
- generator load transfer / AMF switchboard applications
- Support
- Controller selection, configuration, switchboard design, generator integration, building load integration / compatibility, testing and commissioning with on-going support.
Learn more — Generator School
All guides →
Almost every conversation about generator sizing starts with two numbers: kVA and kW. They sound similar, they're closely related, and they're almost always mis-used. The beer-glass analogy below is the fastest way to get them straight in your head — and once you do, every spec sheet in the catalogue suddenly makes sense.

A generator is really three machines bolted together: an engine, an alternator, and a controller. They each do one job, and they all have to talk to each other for the unit to behave properly.

Almost every customer who asks us 'should I get diesel or petrol?' gets the same answer: it depends on the duty. For occasional camp / weekend use under 8 kVA, petrol is cheaper to buy and lighter to move. For anything that has to start reliably after sitting unused — backup, standby, prime-power — diesel wins, almost always.